| With the development of national economy, the Chinese telecommunications industry, especially mobile communications business has become the increasingly significant role in the national economy, telecommunications power as a communication system based on the dynamic supporting its effective monitoring to ensure the stable operation is to protect the communication network security basis.As the communications industry serving the social and economic services in the nature of public life, the continuity of its services, real-time and quality requirements to the communications power supply and communications equipment make the work environment demands higher;At the same time the rapid economic power supply shortage caused by the development of social reform and transition, the social disharmony factors, combined with mobile communication base stations are often in remote rural areas, the current power monitor to communications-based communication systems increasingly can not meet The current communication needs of production, mainly in the following areas:1, electricity consumption has become an important communications company operating costs, can not provide strong support for energy saving;2, the current simple environmental monitoring is not enough to cope with the current society, "theft, sabotage," such as disharmony and there is no adequate early warning and forensic capabilities;In this thesis, based on most existing provincial communication bureau power station which has been built on the basis of environmental monitoring systems, based on IT technology, sensor technology, video surveillance technology, from communications integrated anti-theft monitoring the station, the angle of energy saving the communications room remote centralized monitoring system for in-depth development and application; It also explained through the GPS positioning technology to implement network management and supervision of maintenance personnel, the implementation of transparent and effective assessment mechanisms. Finally,it makes a summary and outlook about power and environment integrated management system for centralized monitoring and a summary and outlook. Depending largely completed the following work:1. ZXM10 communications room based on dynamic environment monitoring system,has designed the base information management module, the energy consumption data assessment analysis report module, power back-analysis of the data service module, the energy consumption data preprocessing module, and other manufacturers of energy consumption data access module. Through calculation by fuzzy logic, control-related equipment, electricity consumption, so as to achieve effective energy conservation goals; relying on the Bureau stations ZXM10 dynamic environment monitoring system, establish an effective data model, development of standard interfaces, through the effective method of calculating energy management system, to construct an effective assessment of energy saving and management mechanism. Multiple base stations for mobile communications in remote areas, urban fringe, often there is the addition of such areas of social security instability, stolen base stations, communication facilities have been destroyed have occurred, the station relies on ZXM10 communication power environmental monitoring system energy-saving Station Communications Agency, with full use of all kinds of advanced sensor technology, building an effective and comprehensive security monitoring tools to ensure the communication network property.2. A detailed analysis of provincial and municipal levels, the Bureau station operation and maintenance management, lower network maintenance costs and other requirements, the analysis of the specific technical requirements, and system construction as the specification, design and implement a comprehensive energy security dynamic environment focused on monitoring and mitigation integrated management system, and tested to achieve the test results, technical reference for implementation of the system but the current maturity of the industry's leading technology appropriately.3. Select Construction of Qingdao, Shandong Province pilot run of 16 points, Qingdao together, there were 1,408 mobile base stations, belonging to eight districts and counties is responsible for maintenance. The system installation, application specific integrated analysis of the problems and make technical improvements, making the system to good practical business needs, verify the practical effects of the system.The main innovation of this thesis: 1. City of corresponding data communication based on the effective management of the station, forming the basis of the database to include intelligent centralized maintenance and management platform, based on data analysis of dynamic power management for communication of the station.2. The control of the temperature detection and effective combination of air-conditioning, the use of effective energy conservation measures, to ensure the stable operation of communications equipment, based on communications companies reduce operating costs.3. Optimize base station security measures to improve the base station/computer room security environment, provide effective protection for network security.The system can be widely used in business operations of the communications room /base station in the comprehensive monitoring and management of all communications operators reduce operating and management costs and improve efficiency of great significance. |