Font Size: a A A

Observation On The Effect Of Electronic Moxibustion Treat Chronic Persistent Of Bronchial Asthma Based On "Tong As The Use Of"

Posted on:2021-04-07Degree:MasterType:Thesis
Country:ChinaCandidate:S M LinFull Text:PDF
GTID:2404330620966775Subject:Acupuncture and massage to learn
Abstract/Summary:PDF Full Text Request
Objective:This study is under the guidance of the teacher's thought of"Tong As the Use of",To observe the effect of electronic moxibustion combined with western medicine and western medicine in the treatment of chronic asthma patients.By exploring the mechanism of electronic moxibustion in the treatment of chronic asthma,we provided a reliable basis for the popularization and application of this therapy.Methods:60 patients with chronic persistent bronchial asthma were collected and randomly divided into two groups.The western medicine group was treated with conventional western medicine inhalation.The electronic moxibustion group was treated with electronic moxibustion on the basis of conventional western medicine inhalation therapy with Dazhui point,Dingchuan point,Zusanli point,Feshu point,Shenshu point and Shanzhong point.The moxibustion lasted 30 minutes each time?moxibustion temperature 45??and 5 times each week.evaluated and calculated in detail before and 8 weeks after treatment,respectively serum IgE content,pulmonary function?one second vital capacity?FEV1?,peak expiratory flow?PEF?actual/expected values?,asthma symptom grading quantification table scoreswere recorded,asthma control test?ACT?questionnaire score was scored before the first electronic moxibustion treatment,4 weeks after treatment and 8 weeks after treatment.By using SPSS20.0 software,the differences between the two groups were analyzed and analyzed.Result:In the course of the study,there were 58 cases in the electronic moxibustion group,29cases in the electronic moxibustion group and 29 cases in the western medicine group.1.Baseline comparison:the age,sex,course and grading baseline of the two groups of patients with chronic persistent bronchial asthma were all the same and comparable.Results of 2.efficacy:?1?results of pulmonary function index determination:before treatment,there was no significant difference in the ratio of pulmonary function FEV1?PEF index measurement between the two groups?P>0.05?.after 8 weeks of treatment,the ratio of pulmonary function FEV1?PEF index measurement in the two groups increased,the difference was statistically significant?P<0.05?,and the improvement of electronic moxibustion group was better than that in western medicine group?P<0.05?.?2?Laboratory indicators:There was no difference in serum IgE content between the two groups before treatment significance of accounting?P>0.05?.After 8 weeks of treatment,the serum IgE content of both groups decreased significantly compared with the previous one?P<0.01?,and the decline level of electronic moxibustion group was better than that of western medicine group?P<0.01?.?3?The ACT scores of the two groups were not statistically significant?P>0.05?.After 4 weeks of treatment,the ACT scores of the two groups were higher than those before treatment?P<0.01?,and the scores of the two groups were not statistically significant?P<0.05?.After 8 weeks of treatment,the scores of the two groups were higher than those of 4 weeks of treatment?P<0.01?,the moxibustion group score was higher than that of western medicine group?P<0.01?.?4?There was no significant difference between the two groups before treatment?P>0.05?.After 8 weeks of treatment,the scores of the two groups were lower than those before treatment?P<0.01?,And the decrease level of electronic moxibustion group was better than that of Western medicine group?P<0.01?.?5?Evaluation of the curative effect:The total control rate of asthma after treatment in the electronic moxibustion group and the western medicine group,respectively of 89.66%and 75.86%,the difference was not statistically significant?P<0.05?,and the total effective rate of clinical symptom score was 100%and 86.21%,respectively,and the difference was statistically significant?P<0.05?.Conclusion:1.The pulmonary function index FEV1 and PEF of patients with chronic asthma were improved by treatment in both groups,and the improvement of electronic moxibustion group was better than that of western medicine group.2.The serum IgE level of patients with chronic asthma was significantly decreased by 2.two groups,and the decreased level of electronic moxibustion group was better than that of western medicine group.3.Two groups can improve the asthma control test?ACT?score of patients with chronic asthma,and the score of electronic moxibustion group is higher than that of western medicine group;4.Both groups can improve the TCM symptoms of patients with chronic asthma,and the score of electronic moxibustion group is better than that of western medicine group.5.The clinical efficacy?total effective rate?and asthma control level?total control rate?of electronic moxibustion group were better than those of western medicine group.
Keywords/Search Tags:The Electronic Moxibustion, Tong As the Use of, Chronic Persistent of Bronchial Asthma, Clinical Efficacy
PDF Full Text Request
Related items