Font Size: a A A

The Design And Implementation Of Multi-user Female Pelvic Floor Pressure Detecting System

Posted on:2017-08-16Degree:MasterType:Thesis
Country:ChinaCandidate:Z M YaoFull Text:PDF
GTID:2322330503972506Subject:Computer technology
Abstract/Summary:PDF Full Text Request
Muscle's strength, as an important indicator to the health status of pelvic floor, is significant to prevent pelvic floor dysfunction illness such as stress incontinence and prolapse of metroptosis. Developing a system to provide full function of testing muscle's strength has a board market application prospect.This article has developed a system to testing the strength of pelvic floor based on the requirement of the user.The system can divided into three part.The first part is the android client program,which is designed to be used by the patient.The client program receive data from the sensor which wear by the patient and collect data from the patient.At the same time,the client program lead the patient to finish the testing by the guide graph and display the real time data on the screen so that the user can see it.The second part is the server program which is used by the doctor.The server program is designed based on the Qt architecture and the program runs on the windows operating system.The server program receive data from the android client program and display it on the software interface.In this way,the doctor can observe the data in real time.Meanwhile,the server program can give orders to the android client program to control the process of the patient's testing program.After finishing the test,the server program can analysis the data collected this time,and generate the result report.The third part is the database server program.The database server program save the data each test generated so that the patient can make comparison while recovering.The system use the idea of object-oriented programming,following the rules of software engineering to reduce the redundancy of the code.The structure of every module of the project is clear and the coupling between modules and modules is low.Meanwhile the project have good extendibility.The client program is based on the android operating system developed with eclipse.While the server program and the database server program is based on the Windows operating system developed with visual studio 2010.The system uses the sqlite database.
Keywords/Search Tags:pelvic, muscle strength detection, Qt, android
PDF Full Text Request
Related items