Font Size: a A A

Measuring aniseikonia using scattering filters to simulate cataract

Posted on:2012-04-24Degree:M.SType:Thesis
University:The University of Alabama at BirminghamCandidate:Wilson, JasonFull Text:PDF
GTID:2454390008498116Subject:Health Sciences
Abstract/Summary:
The relationship between anisometropia and aniseikonia (ANK) is not well understood. Ametropic cataract patients provide a unique opportunity to study this relationship after undergoing emmetropizing lens extraction. Because light scatter may affect ANK measurement in cataract patients, its effect should also be evaluated.;The Basic Aniseikonia Test (BAT) was evaluated using afocal size lenses to produce specific changes in retinal height. Several light scattering devices were then evaluated to determine which produced effects most similar to cataract. Contrast sensitivity and visual acuity (VA) losses were measured with each device and compared to those reported in cataract. After determining the most appropriate light scattering device, twenty healthy patients with normal visual function were recruited to perform the BAT using the filters to simulate cataract.;Cataract patients were recruited from Vision America and the University of Alabama at Birmingham School of Optometry. Patients between 20 and 75 years of age with at least 20/80 VA in each eye, ≥ 2D ametropia, and normal binocular function were recruited. Stereopsis and ANK were tested and each patient completed a symptom questionnaire.;ANK measurements using afocal size lenses indicated that the BAT underestimates ANK, although the effect was minimal for vertical targets and darkened surroundings, as previously reported. Based on VA and contrast sensitivity loss, Vistech scattering filters produced changes most similar to cataract. Results of the BAT using Vistech filters demonstrated that a moderate cataract but not a mild cataract may affect the ANK measurement.;ANK measurements on cataract patients indicated that those with ≥ 2 D ametropia in each eye may suffer from induced ANK after the first cataract extraction. With upcoming healthcare reform, unilateral cataract extraction may be covered, but not necessarily bilateral, depending on patient VA in each eye. However, a questionnaire about symptoms at each visit in the current study showed that visual comfort did not improve after unilateral, but did improve after bilateral, cataract extraction. This indicates that quality of life should be better in bilateral cataract patients only if both cataracts are removed. This is supported by the findings of other studies.;Keywords: Aniseikonia, Anisometropia, Cataract, Ametropia.
Keywords/Search Tags:Cataract, Aniseikonia, ANK, Using, Scattering, Filters, BAT
Related items