Font Size: a A A

Clinical Resach About Therapy Of Urinary Incontinence After Stroke By Electro-acupuncture Baliao-point Combined With Moxibustion

Posted on:2012-05-28Degree:MasterType:Thesis
Country:ChinaCandidate:X Y ChenFull Text:PDF
GTID:2214330368476449Subject:Chinese medicine
Abstract/Summary:PDF Full Text Request
Objective:to introduce therapy of urinary incontinence after stroke by electro-acupuncture activate baliao-point Combined with moxibustion and to evaluate its outcome.Methods:60 inpatients with urinary incontinence after stroke were selected from the Department of acupuncture,Affiliated Hospital of Integrated Traditional Chinese and Western Medicine of Tongji Medica College,Huazhong University of Science and Technology between July 2009 and May 2010, and randomly divided into treatment group(n=30),which was treated by electro-acupuncture activate baliao-point,30 minutes every time, then pull out the acupuncture and put the moxa box with live moxa on qihai and guanyuan points, once daily,A course of treatment is two weeks, And control group(n=30),which taken traditional Chinese medicine(suo quan Pill). Taken 6g once time,three times a day and take the pills two weeks as a cours of treatment. Through observing The patients clinical score and the The urodynamic examination results compared with that before treatment, study on the clinical therapeutic of treatment therapy of urinary incontinence after stroke by electro-acupuncture activate baliao-point Combined with moxibustionResult:The clinical score of the treatment group were improved significantly compared with that before treatment [(9.52±1.46), (3.15±1.60)]and the urodynamic examination results of the treatment group were improved significantly compared with that before treatment [initial volume of bladder filling:(126.36±24.85), (247.88±48.85) ml, maximum volume of bladder:(339.70±41.57), (549.39±81.85) ml residual urine volume (83.03±13.34), (49.39±11.71) P<0.05]. We compared the elinical effieacy after the treatment:the treatment group:10 cured,12 marked,7 positive,1 inefficacy; the controlgroup:3 cured,7 marked,12 positive,8 inefficacy。We compared the two groups with Ridit analysis, (p<0.05) and this indicated that the efficacy of the treatmen tgroup was superior to the control group.Conclusion:the treatment group was better than the control group and the signs and symptoms of patients have remarkably improved。...
Keywords/Search Tags:Urinary incontinence after stroke, Baliao-point, Electro-acupuncture activate, moxibustion
PDF Full Text Request
Related items