A durable, load-bearing, muscle-to-prosthesis coupling for circulatory support power: Conception, design and development, testing, and intellectual property

Posted on:2003-12-05Degree:Ph.DType:Thesis
University:The Ohio State UniversityCandidate:Melvin, David BoydFull Text:PDF
GTID:2462390011983658Subject:Engineering
Abstract/Summary:
Many die yearly of heart failure despite present treatment. A frequently suggested treatment innovation uses multiple conditioned and paced skeletal muscles, linked to drive already-proven mechanical support devices.; But adequately durable muscle-prosthetic bonding has never succeeded. Tissue simply cannot long tolerate pressures generated—up to 40,000 mmHg—at the tissue/prosthetic interface when needed forces (100 or more Newtons) are borne by sutures or clamps.; Dramatically increasing force-transfer surface, by dispersing ultrafine polymer fibers distally in muscle, may solve this. A device was conceived, developed and tested. This dissertation comprises mathematical exploration, three sequential experimental studies confirming principles, and a US patent.; An Introduction presents the problem's significance: the human and economic need for effective mechanical heart failure treatment, the lack of a safe, effective power supply, and the role a successful muscle-to-prosthetic coupling could play in a solution.; Then, computational and initial experimental examinations are Chapter 1, published in a peer-reviewed journal. Pull-out strength in a pilot 30 day rabbit test was nine times that needed.; Other investigators, at a separate institution with a canine latissimus model, collaborated with the student in confirmatory work, with strength again far exceeding need. This (Chapter 2) is also a peer-reviewed publication.; In the final experiments described (Chapter 3), the postulated tissue integration of the fibers was explored using the rabbit posterior tibial model in more animals for longer times (up to 90 days), with contralateral buttressed-suture controls. More-than adequate bond-strength was shown stable over this longer period. Histologically, there was indeed thorough integration: over 85% of sampled surface points were adjacent solid tissue structures. The hypothesis—that this type achieves its strong durable bond by thorough tissue integration—was shown true.; The student has patented the device (US 6,214,047, 10 April, 2001). The patent is included as Chapter 4.; The application of this technology for the original intent of mechanical circulatory support power and also for unmet orthopaedic applications requiring muscle-to-prosthesis fixation continues.
Keywords/Search Tags:Support, Power, Durable
Related items