Performance evaluation of single and double-basin solar stills in Las Vegas, Nevada

Posted on:2008-12-13Degree:M.S.EType:Thesis
University:University of Nevada, Las VegasCandidate:Holur Venkatesh, NandaFull Text:PDF
GTID:2440390005963446Subject:Engineering
Abstract/Summary:
The objectives of this research were to conduct long-term testing of modified single-basin still designs, and to design, build and test an alternative double-basin still that may increase water production at the same or lower cost.; Performance of two commercial single-basin still designs, from different suppliers, was evaluated over a 14-month period in Las Vegas, Nevada. The average daily water yields of SunwaterRTM and SolAqua(TM) ranged from 1.1+/-0.7 L/m2 and 0.9+/-0.5 L/m 2 (in winter) to 5.5+/-1.7 L/m2 and 4.6+/-0.9 L/m2 (in summer) respectively.; Different configurations of cover glass and water volume/depth were evaluated on SunwaterRTM single-basin stills. Low-e glass was found to produce 14.7% less water than standard clear glass. Water yield was generally not sensitive to operating water depth.; A double-basin prototype was constructed and tested. It had an average daily yield of 0.47 L/m2, while the standard stills produced in the range of 1.8-2.9 L/m2.
Keywords/Search Tags:Stills, L/m2, Double-basin