Evaluation Of Left Ventricular Diastolic Function By Flow Propagation Velocity Of Under The Mitral Valve Using Dual Doppler Echocardiography

Posted on:2021-01-06Degree:MasterType:Thesis
Country:ChinaCandidate:Y HanFull Text:PDF
GTID:2404330602498850Subject:Imaging and nuclear medicine
Abstract/Summary:PDF Full Text Request
Objective:The flow propagation velocity?vp?of under the mitral valve in early left ventricular diastolic period was detected by dual pulsed wave Doppler?PW?,and dual Doppler echocardiography was compared with M-mode color Doppler by evaluating left ventricular diastolic function of normal subjects and patients.Methods:A total of 128 patients of outpatient and inpatient in The People's Liberation Army Joint Service Support Force No.967 Hospital from March 2019 to September 2019 were selected.According to the inclusion criteria and exclusion criteria,78 patients were excluded.Finally,a total of 50 patients were included in the study.There were 30 males and 20 females.In addition,24 healthy volunteers were included as the control group,including 14 males and 10 females.We collected clinical parameters including gender,age,blood pressure,blood glucose,coronary artery disease and clinical history.We also collected ultrasonic parameters including early diastolic velocity by the side of mitral annulus spacing?e'?,the early-diastolic peak velocity of the transmitral flow?E?,the late-diastolic peak velocity?A?,E/A ratio,left atrial systolic diameter,interventricular septum,left ventricular posterior wall,left ventricular diastolic long diameter and left ventricular long diameter,left ventricular diastolic short diameter and left ventricular systolic short diameter.Value of vpmeasured by dual Doppler echocardiography(vp PW):from the apical four-chamber view,the first sample volume was placed at the mitral valve?D1?.Another sampling volume was placed at 4cm?S?from the mitral valve to the apex of the heart?D2?.The anterior transmitral flow spectrum was recorded synchronously at both sites.According to the synchronous electrocardiogram,the time difference??T?at the beginning edges of the two spectrums at D1 and D2 is measured during the same cardiac period.Calculation of the value of vp(vp PW)according to V?vp?=S/?T.Value of vp(vp M)measured by M-mode color Doppler:in the M-mode color Doppler mode,M-mode color Doppler images of left ventricular diastole period were displayed on the apical four-chamber view.We measured the slopes of the isovelocity lines.The difference and correlation of dual PW Doppler,M-mode color Doppler and other related indexes in the patient group and control group were compared.The reproducibility between interobserver and intraobserver was compared.The measurement reproducibility of dual PW and M-mode color Doppler was compared by Med Calc.Results:1.Comparisons of general dataSystolic blood pressure,diastolic blood pressure,heart rate and fasting blood glucose in the patient group were significantly higher than those in the control group?P<0.05?,but there was no significant difference between the two groups in age and gender?P>0.05?.2.Comparisons of conventional parameters of echocardiographyIn the patient group,interventricular septum,left ventricular posterior wall,left ventricular diastolic long diameter,left ventricular systolic long diameter,left ventricular diastolic short diameter,left atrial systolic diameter and A were significantly higher than those in the control group,e'was significantly lower than that in the control group?P<0.05?,while there was no significant difference between the two groups in E,E/A and left ventricular systolic short diameter?P>0.05?.3.Comparisons of vp PWand vp MIn the patient group,vp PWand vp Mwere significantly lower than those in the control group?P<0.05?.Within the patient group,there were significant differences in vp PWand vp M?P<0.05?;Within the control group,there were significant differences in vp PWand vp M?P<0.05?.In all subjects,vp PWwas significantly related to vp M?r=0.905,P< 0.05?,vp PWwas moderately related to e'?r=0.465,P<0.05?,and vp Mwas moderately related to e'?r=0.488,P<0.05?.4.The reproducibility of vpbetween interobserver and intraobserverICCs of Dual PW intraobserver?0.94?and interobserver?0.85?are better than ICCs of M-mode color Doppler intraobserver?0.81?and interobserver?0.71??P<0.05?.5.Comparison of measurement reproducibility between dual PW and M-mode color DopplerThe analysis of Bland-Altman showed that the difference of vpbetween M-mode color Doppler and dual PW about 96%was in the 95%limits of agreement.Conclusion:Dual PW Doppler can replace M-mode color Doppler.And dual PW Doppler can better evaluate left ventricular diastolic function than M-mode color Doppler.
Keywords/Search Tags:dual pulsed wave Doppler, flow propagation velocity, M-mode color Doppler, left ventricular diastolic function
PDF Full Text Request
Related items
Clinical Study Of The Relationship Between Regional Left Ventricular Relaxation Asynchrony And Early Diastolic Flow Propagation Velocity In Hypertensive Patients
Clinical Study Of The Relations Between The Left Ventricular Early Diastolic Flow Propagation Velocity And Left Ventricular Regional Diastolic Function As Well As Hypertrophy In Hypertrophic Cardiomyopathy
Alteration Of Left Ventricular Early Diastolic Flow Propagation Velocity In Patients With Essential Hypertension And Its Clinical Significance
The Study Of The Time Difference Between Pulse Wave Propagation Velocities In Vessel Wall And Flow Using Dual Pulsed-Wave Doppler Echocardiography
Evaluation Of The Relationship Between Color M-mode Doppler Flow Velocity And The Left Ventricular Spherical Index
The Study On The Relationship Of The Left Ventricular Flow Propagation Velocity And Changes In Left Ventricular Morphology As Well As Left Ventricular Filling Pattern In Patients With Acute Myocardial Infarction
Evaluation Of Effect Of Obesity On Left Ventricular Diastolic Function By Echocardiography
Detection Of The Left Ventricular Function In Diabetes Mellitus Using Pulsed Wave Tissue Doppler Imaging And Quantitative Tissue Velocity Imaging
Clinical Utility Of Doppler Echocardiography In The Estimation Of Diastolic Function With Coronary Heart Disease-A Comparative Simultaneous Doppler Cardiography-Catheterization Study
10 The Clinical Research Of Assessment Of Left Ventricular Diastolic Function In Type-2 Diabetes Mellitus By Tissue Doppler Imaging Measuring Mitral Annular Motion