Dosimetry Study On A-Si EPID

Posted on:2009-12-23Degree:MasterType:Thesis
Country:ChinaCandidate:Q H WuFull Text:PDF
GTID:2144360272991691Subject:Biomedical engineering
Abstract/Summary:PDF Full Text Request
Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. With the development of radiotherapy techniques and EPIDs, they are increasingly used as tools for linac specific quality assurance (QA) and dosimetric verification. However, Studied on using scanning liquid ionization chamber EPIDs were published mostly in the literature of recently 10 years, which drew discontented conclusions in dosimetric verification.This study reviews the types of EPIDs, intensity modulated radiation therapy (IMRT) and its QA methods, the clinical application of EPIDs specially in the IMRT verification, and also introduces the hardware and components of Varian PortalVision(PV) aS500 Amorphous Silicon (a-Si) EPID, and its calibration methods.Based on MATLAB language, over 30 special functions are programmed with more than 3000 lines' code, and an in-house software tool is developed to achieve the following functions: to read and write, process, analyze, show and chart the data. Varian 21EX Linac's PV aS500 a-Si EPID is studied, the dose images from treatment planning system (TPS) and EPID are exported and read in ASCII, and the data's characteristics are analyzed. Based on some hypothesis, the relations between EPID value (EV) and monitor unit (MU) or EPID dose (ED) are developed. The dose calibration curves of the EPID are established, and the errors of curves are analyzed. The images of the EPID and TPS are spatial registered and scaled. Distance to agreement (DTA) analysis is applied to the EPID's dosimetric verification.One prostate cancer patient and one nasopharyngeal carcinoma (NPC) patient are selected to design some plans using 3 dimension conformal radiation therapy (3DCRT) and IMRT techniques. Based on the above study, comparing to MapCheck, the EPID is used to do clinical dosimetric verification. In summary, the result of EPID is not as good as MapCheck. To get the similar pass rate, the DTA error criterion of MapCheck is good than EPID by one or two levels, which is possibly caused by EPID's narrow penumbra and the errors from the algorithms of spatial registration and DTA in this study.This study presents exploratory research on the dosimetry of a-Si EPID, and develops a software tool. Although the current preliminary result is not good as expected, the study lays the foundations for the next step to dosimetry research of the a-Si EPID.
Keywords/Search Tags:EPID, a-Si, IMRT, dosimetry verification, MATLAB
PDF Full Text Request
Related items