Font Size: a A A

Analysis Of The Infilled RC Framed Subjected To Horizontal Loading

Posted on:2011-01-03Degree:MasterType:Thesis
Country:ChinaCandidate:X J PuFull Text:PDF
GTID:2132330332973845Subject:Structural engineering
Abstract/Summary:PDF Full Text Request
Infilled reinforced concrete structure with the framework is a widely used in residential and commercial premises, offices and the structure of the system..This structure is widely applied and its structural arrangement is proper. According to the need to the position of the wall, and the division of space, so it has the best adaptability. To design, the recommendation of the beams and columns considered for the main force members, the wall only be considered as Load. This calculation method enables the design of the situation and actual the situation not consistent.The arrangement of the wall not only increases the structural loads,but also adds A constraint to the beams and columns,changging the internal force of the structure. Many studies show that the Infilled might influence the bearing capacity of the structure, deformation, lateral stiffness, ductility and so on.In this paper, we use ANSYS modeling to analysising a one-storey single-cross specimens of infilled frame model subjected with impersonated method. Compare with experiment to obtain a reasonable parameters and units. Basis on this, we can establish a single double-cross Pin infilled frame model, using the ANSYS nonlinear analysis to understand the filling wall height, thickness, wall materials, masonry beam-column linear stiffness of manner and Frame Structure, deformation, damage form of rigidity, etc; The article also established a three-storey single-span specimens of infilled frame model, using the ANSYS modal analysis,to understand the effecf of infilled to the framework of the self-filling wall of the earthquake cycle, frequency and stiffness. We use non-linear ANSYS analysis to understand the vertical stiffness of the formation of non-uniform arrangement of the weak layer of the wall on the lateral stiffness of the framework to identify the most unfavorable layout.In structural designing, we can refer to conclusions of this article, but you should take careful consideration the serious adverse effects of structural factors, selecting the favorable arrangement of the infilled walls.
Keywords/Search Tags:infilled wall, frame structure, finite element, nonlinear, nonlinear static analysis, weak layer
PDF Full Text Request
Related items