Font Size: a A A

Characterizing and modeling protein-surface interactions in lab-on-chip devices

Posted on:2010-10-25Degree:Ph.DType:Dissertation
University:University of FloridaCandidate:Katira, ParagFull Text:PDF
GTID:1440390002476896Subject:Engineering
Abstract/Summary:
Protein adsorption on surfaces determines the response of other biological species present in the surrounding solution. This phenomenon plays a major role in the design of biomedical and biotechnological devices. While specific protein adsorption is essential for device function, non-specific protein adsorption leads to the loss of device function. For example, non-specific protein adsorption on bioimplants triggers foreign body response, in biosensors it leads to reduced signal to noise ratios, and in hybrid bionanodevices it results in the loss of confinement and directionality of molecular shuttles. Novel surface coatings are being developed to reduce or completely prevent the non-specific adsorption of proteins to surfaces.;A novel quantification technique for extremely low protein coverage on surfaces has been developed. This technique utilizes measurement of the landing rate of microtubule filaments on kinesin proteins adsorbed on a surface to determine the kinesin density. Ultra-low limits of detection, dynamic range, ease of detection and availability of a ready-made kinesin-microtubule kit makes this technique highly suitable for detecting protein adsorption below the detection limits of standard techniques.;Secondly, a random sequential adsorption model is presented for protein adsorption to PEO-coated surfaces. The derived analytical expressions accurately predict the observed experimental results from various research groups, suggesting that PEO chains act as almost perfect steric barriers to protein adsorption. These expressions can be used to predict the performance of a variety of systems towards resisting protein adsorption and can help in the design of better non-fouling surface coatings.;Finally, in biosensing systems, target analytes are captured and concentrated on specifically adsorbed proteins for detection. Non-specific adsorption of proteins results in the loss of signal, and an increase in the background. The use of nanoscale transducers as receptors is beneficial from the point of view of signal enhancement, but has a strong mass transport limitation. To overcome this, the use of molecular shuttles has been proposed that can selectively capture analytes and actively transport them to the nanoreceptors. The effect of employing such a two-stage capture process on biosensor sensitivity is theoretically investigated and an optimum design for a kinesin-microtubule-driven hybrid biosensor is proposed.
Keywords/Search Tags:Protein, Surface
Related items