Font Size: a A A

Design Of SF6 Gas Detector-based On NDIR Technology

Posted on:2019-06-28Degree:MasterType:Thesis
Country:ChinaCandidate:S Y ChenFull Text:PDF
GTID:2382330563993321Subject:Optical Engineering
Abstract/Summary:PDF Full Text Request
SF6 gas is widely used in power systems because of its high stability,strong electrical insulation strength and excellent arc extinguishing performance.However,the leakage of SF6 gas is a ubiquitous and unavoidable problem due to the differences in manufacturing processes,production,installation and the aging of equipment.Once the SF6 gas leak occurs,it will cause huge losses to the state’s property,even seriously endanger the health of the workers.Therefore,it is of great significance to the development of SF 6 gas concentration detection system.Based on the theory of infrared spectrum absorption,this thesis designed a set of SF6gas concentration detection system based on NDIR(non-dispersive infrared)technology with small size and high measurement accuracy.The main research contents are as follows:(1)The measurement theory of SF6 gas concentration based on infrared spectrum absorption was elaborated in detail,and the measurement advantages of non-dispersive infrared technology were compared with the common measurement methods of SF6 gas concentration.(2)A set of SF6 gas concentration measurement system was designed and completed,including device selection,circuit system,GUI(Graphical User Interface)design,and temperature compensation algorithm design.Among them,a pyroelectric detector for SF6gas with dual-channel was used,the output electrical signal of dual-channel,including the signal channel and the reference channel,can inhibit the influence of unstable infrared light,dust and other factors;In circuit systems,combined with the characteristics of pyroelectric detectors with low peak-to-peak of output AC signal,high DC bias,and low signal-to-noise ratio,two-order bandpass filters and high-gain instrumentation amplifiers were designed to perfectly extract the voltage signals of detector,which has a high signal-to-noise ratio;The minimum system was designed by using STM32microcontroller,as the control center of the slave computer and data communication with the host computer;GUI could complete the real-time drawing of the channel curve and concentration curve,display temperature,save the picture and other functions;Lambert-Beer’s law was corrected,and the algorithm of temperature compensation was proposed to correct the effect of temperature on gas concentration measurements.(3)The testing of SF6 gas concentration detection system was completed,including circuit test,concentration calibration test and temperature change test.The experimental results showed that the detection system designed in thesis can accurately measure SF6 gas in the range of 0-10000ppm.The repeatability and stability of the measurement could meet the actual requirements.
Keywords/Search Tags:Non-Dispersive Infrared technology, SF6 gas, Graphical User Interface, The algorithm of temperature compensation
PDF Full Text Request
Related items