Font Size: a A A

Imaging Studies Of The Surface Location Of Sustentaculum Talus And Its Projection Coordinates On The Lateral Calcaneal Wall And Its Significance

Posted on:2017-05-12Degree:MasterType:Thesis
Country:ChinaCandidate:J Q WangFull Text:PDF
GTID:2284330488456360Subject:Hand orthopedic trauma surgery
Abstract/Summary:PDF Full Text Request
Objective Nowadays, the surgery for calcaneal fractures have been widely recognized by the people。However, due to the complex shape of the calcaneus, deep position of the sustentacular process, during the operation, doctors tend to screw to the sustentaculum talus protruding from the carrier by their clinical experience, however, the location of the screw is unsatisfactory, sometimes could injury the medial structure and joint cavity. This topic is mainly through imaging related data from sustentaculum talus to create a "safe passage" between sustentaculum talus and the lateral wall of calcaneus.Method Select 30 adult foot and ankle CT scan+3D reconstructed image as a specimen and all information were provided from the First Affiliated Hospital of Guangxi Medical University of Radiology,and sweeping surface equipment be the United States ranked 128 GE64-slice spiral CT (Light-speed VCT), data processing Workstation software for Advantage Workstation volumeshare4.0. Measure the distance of sustentaculum talus to the front of the tibia, and the length, width, front lean angle, On the flip Angle of sustentaculum talus On the 3D reconstruction images.Results The distance of sustentaculum talus to the front of the tibia was (34.45±2.64)/(28.40-41.50) mm, the length of sustentaculum talus was (20.13±1.76mm)/(17.70~24.80)mm, the width of sustentaculum talus was (10.23±1.14)/(7.80~13.10) mm, the front lean angle was (30.54±4.71)°/(21.60~38.80)°, on the flip Angle was (25.33~6.40)°/(18.20~37.50)°, the projection coordinates of sustentaculum talus on the lateral calcaneal wall, XA’19.14±1.47 (16.70~21.30) mm,YA’20.12±1.40 (17.90~22.30) mm;XB’1.21 ±1.56 (-1.30~3.60) mm,YB’8.31±1.08 (6.70-10.10) mm;XC’-3.29 ±2.86(-7.70~1.20)mm,YC 11.81±1.70(9.10~15.50)mm;XD’11.71 ±1.36 (9.50~13.80) mm, YD’24.82±2.34 (21.60~28.50) mm, the reference length of screw to sustentaculum talus was 46.58±4.51 (40.30~54.50) mm.Conclusion This study shows the sustentaculum talus position on the body surface, the projection coordinates of sustentaculum talus on the lateral calcaneal wall and the reference length of screw, improves the accuracy and security in Calcaneal fracture surgery, the treatment of calcaneal fracture with internal fixation has a certain significance.
Keywords/Search Tags:Sustentaculum talus, Projection coordinates, Safe passage
PDF Full Text Request
Related items