Font Size: a A A

RT-3DE Versus640-MSCT For Quantitative Assessment Of Left Ventricular Volume And Systolic Function In Patients With Coronary Heart Disease

Posted on:2013-12-11Degree:MasterType:Thesis
Country:ChinaCandidate:J ZhangFull Text:PDF
GTID:2254330401457220Subject:Medical imaging and nuclear medicine
Abstract/Summary:PDF Full Text Request
Purpose:To explore the dependency and application value of real-time three-dimensional (RT-3DE) and640-MSCT on the left ventricular volume and systolic function. We evaluate left ventricular volume and systolic function in patients with coronary heart disease quantitatively, using RT-3DE and640-MSCT.Methods:42cases of coronary heart disease patients confirmed by clinical or coronary angiography were enrolled in this study randomly. We use640-MSCT to obtain the left ventricular volume and cardiac function, using Automatic method and Manual method. Meanwhile, RT-3DE full-volume image technology with the measured data for comparison, including EDV, ESV, SV, EF%. We compared RT-3DE with640-MSCT in cardiac function measured values. Results:1) The data of640-MSCT manual survey and that of auto survey were similar and had higher correlation coefficient.(r>0.90); The data left ventricular volume and function of640-MSCT manual survey and that of auto survey were no significant differences;2) The data of left ventricular volume and function indicators (EDV, ESV, EF%, SV) tested with RT-3DE and that with640-MSCT manually measured values and automatically measured values were good correlation(r>0.90, q>0.05);3) The difference between640-MSCT automatically measured values and RT-3DE in left ventricular volume and cardiac function is that the640-MSCT automatically measured values of EDV and ESV were higher than of RT-3DE (q <0.05), it is slightly higher than RT-3DE of SV (q>0.05),but it is slightly lower than RT-3DE of EF (q>0.05);4) The difference between640-MSCT manually measured values and RT-3DE in left ventricular volume and cardiac function is that the640-MSCT manually measured values of EDV and ESV were higher than of RT-3DE (q<0.05), it is slightly higher than RT-3DE of SV (q>0.05),but it is slightly lower than RT-3DE of EF (q>0.05).Conclusion:Both of this method have advantages and disadvantages. We combine640-MSCT with RT-3DE, according to different illnesses and their characteristics. This proves the imaging diagnosis of clinical illnesses and provides enough message for diagnosis and treatment.
Keywords/Search Tags:real-time three-dimensional echocardiography, 640MultisliceComputed Tomography, left ventricular volume and systolic function
PDF Full Text Request
Related items
A Comparative Study Of The Left Ventricular Systolic Function In Patients With Coronary Artery Diseas By Real-time Three-dimensional Echocardiography And Two-dimensional Echocardiography
Assessment Of Global And Regional Left Ventricular Systolic Function By Real Time Three Dimensional Echocardiography: Clinic Applications And In Vivo Study
Assesment Of Global And Regional Systolic Function Of Left Ventricular In Patients With Coronary Artery Disease After Treatment By Volume-time Curves Of Real-time Three-dimensional Echocardiography Therapy
An Observation Of Hemodynamics, Cardiac Chamber Size And Left Ventricular Systolic Function In Patinets With Ventricular Septal Defect Before And After Occlusion By Echocardiography
Real-time Three-dimensional Echocardiography To Evaluate The Stability Research Of Left Ventricular Diastolic Function In Patients With Coronary Heart Disease (chd)
Evaluation Of Right Ventricular Systolic Function And Left Ventricular Systolic Function In Patients With Pulmonary Embolism By Single Cardiac Cycle Real-time Three Dimensional Echocardiography
The Application Of Real-time Three-dimensional Echocardiography In Patients With Left Ventricular Systolic Function In Coronary Heart Disease Diagnosis
Clinical And Experimental Evaluation Of Right Ventricular Global And Regional Volume And Systolic Function Using Real-time Three-Dimensional Echocardiography
Study On Evaluating Cardiac Function And Synchronism In The Patients With RV Pacing At Different Sites By Real-time Three-dimensional Echocardiography
10 The Influence Of Percutaneous Closure And Surgical Repair Of Ventricular Septal Defect On Left Ventricular Function And Systolic Synchrony Assessed By Real-time Three-dimensional Echocardiography