Abstract/Summary:PDF Full Text Request
Objective:TO Observe the Clinical efficacy of interlocking intramedullary nail and Lockingcompression plate to therapy the Nonunion of Femur Fractures by the Plate FixationMethods:Retrospective study of the48Nonunion Femur Fractures Treated by the Plate Fixationfrom January2000to June2011.There are25cases Re-treatment by interlocking intramedullarynail,and13cases Accepted Autogenous iliac bone gratf and23by Locking compression plate,and allAccepted Autogenous iliac bone graft.To guide patients limp Functional exercisePost-operative,inform the patients to Shooting X-Ray in time,check the limp function and record theoutcome by special people.Result:The mean operation time of the interlocking intramedullary nailgroup shorter than Locking compression plate group(p<0.05),The Locking compression plate grouphas the shorter clinical union time,and the The long-term efficacy has nodeference(p<0.05).Conclusions:Both methods can make ideal clinical efficacy,clinicians should bechoose the most beneficial internal fixation for Patients.
Keywords/Search Tags:Femoral shatf fracture, Internal fixation failure, Nonunion, Interlockingintramedullary nail, Locking compression plate