The Comparison Of Glucose Measurements Between Capillary Whole Blood Glucose And Venous Plasma Glucose For Residents In Qingdao

Posted on:2009-10-31Degree:MasterType:Thesis
Country:ChinaCandidate:K J HuangFull Text:PDF
GTID:2144360272456399Subject:Nutrition and Food Hygiene
Abstract/Summary:PDF Full Text Request
Objective To evaluate the difference and correlation of glucose measurements between capillary whole blood glucose and venous plasma glucose on fasting in Qingdao,and to evaluate the capillary whole blood glucose with relative operating characteristic curve.Methods 3647 residents above twenty-six were questioned and measured by multi-stage cluster random sampling in the six districts of Qingdao.Vein blood was taken out to measure the sugar values,at the same time,the capillary whole blood was sampled from the fingertip by glucose monitor.The data obtained were then analyzed with statistical means.Results The average level of capillary whole blood glucose(6.20±2.05 mmol/l) was less than venous plasma glucose(6.31±2.35 mmol/l,and there was significant difference in the level of blood glucose between them(t'=6.04,P<0.01).The relevant differences between venous plasma glucose and capillary whole blood glucose were less than 7%.Prevalence rate of diabetes mellitus was 17.5%and 18.9%respectively, there was no significant difference between them(P>0.05).The correlation coefficients between venous plasma glucose and capillary whole blood glucose was 0.860.When critical value of capillary whole blood glucose was 6.85mmol/l,the area below ROC curve was 0.899,sensitivity and specificity were 76.8%and 93.4% respectively,false positive proportion was 23.2%,false negitive proportion was 6.6%, positive predictive value was 69.3%,negative predictive value was 95.4%,positive likelihood ratio was 11.63,negitive likelihood ratio was 0.248,Youden index was 0.702.Conclusions Glucose monitor showed very good repeatability.Capillary whole blood glucose have good concordance with venous plasma glucose,but venous plasma glucose could not diagnose diabetes mellitus instead by capillary whole blood glucose.Glucose monitor has more cut off-values for the diabetes.
Keywords/Search Tags:Diabetes mellitus, Capillary whole blood glucose, Venoua plasma glucose
PDF Full Text Request
Related items
Analyses Between Oral Glucose Tolerance Test Characteristics And Adverse Pregnancy Outcomes Among Women With Gestational Diabetes Mellitus
The Value Analysis Of Mid-pregnancy Fasting Plasma Glucose,GA And HbA1c For Gestational Diabetes Mellitus With Normal Fasting Plasma Glucose
The Study Of The Diagnostic Values Of Glycosylated Hemoglobin On Abnormal Glucose Metabolism In The Middle Aged And Elderly Population
The Meaning Of Each Time Point Plasma Glucose At OGTT In Diagnosis Of Abnormal Glucose Metabolism And The Characteristics Of Glucose Metabolism Of 1h Hyperglycemia
Combination Use Of HbA1c And Plasma Glucose Improves The Efficiency Of HbA1c In Diagnosing Diabetes In Chinese With Increased Risk For Diabetes
Real-Time Observation Of Blood Glucose Fluctuates In Type 2 Diabetes Patients After Intaking Three Different Breakfast By Using Continuous Glucose Monitoring System
Characteristics Of Glycemic Fluctuation In Gestational Diabetes Mellitus Different Fasting Plasma Glucose Level And The Influence Of Diet Therapy The Glucose Variability
Correlations Between HbA1c, Fasting Glucose,2h Postload Glucose And β-cell Function In The Chinese Population
The Differences In Outcomes,Insulin Function And Insulin Resistance At 6-8 Weeks Postpartum Among The Pregnant Women With Gestational Diabetes Mellitus Under Different Glucose Metabolism States
10 Investigation of the predictability of blood glucose dynamics, based solely on preceding blood glucose measurements and implications for the treatment of diabetes mellitus