Font Size: a A A

Spect brain imaging of the dopaminergic system in Parkinsonism using iodine-123 and technetium-99m labeled agents

Posted on:2005-12-30Degree:Ph.DType:Dissertation
University:The University of North Carolina at Chapel HillCandidate:Du, YongFull Text:PDF
GTID:1454390008480914Subject:Engineering
Abstract/Summary:
SPECT brain imaging of the dopaminergic system using 123I and 99mTc labeled agents, especially the simultaneous imaging of both pre- and post-synaptic neurons, promises to provide accurate diagnosis and differentiation of Parkinsonism. However there are many degrading factors that affect the quality and quantitative accuracy of the SPECT images. These degrading factors limit the potential clinical applications of brain SPECT imaging. In this work, we studied these degrading factors by developing and validating a Monte Carlo (MC) method that provides accurate SPECT simulation with detailed modeling of the photon interactions inside the collimator detector system. To compensate for the partial volume effect (PVE) in the SPECT images caused by finite spatial resolution, we developed a new PVE compensation method that takes into account the effects of nonlinearity in iterative of reconstruction-based compensation for image degrading factors, including attenuation, scatter, and collimator detector response. Compensation using the new method greatly improved the quantitative accuracy of brain SPECT images. We have also developed model-based method that can accurately estimate the downscatter and crosstalk contamination in the 123I imaging and the simultaneous 123I/99mTc dual-isotope imaging. Based on the model-based method, two different approaches to model-based downscatter and crosstalk contamination compensation were proposed. Both methods are based on iterative reconstruction and include compensation for other imaging degrading factors. The model-based downscatter and crosstalk compensation method provided greatly improved accuracy of activity estimates with little effect on the precision. Finally, optimization of energy windows for simultaneous 99mTc/ 123I acquisition was performed to find the energy windows with the best tradeoff between minimizing the crosstalk and maximizing the detection efficiency for simultaneous acquisitions. In summary, comprehensive methods were developed and evaluated to compensate for image degrading factors in simultaneous dual-isotope brain SPECT image. Application of these methods in the imaging of the dopaminergic system has the potential to provide improved accuracy for diagnosis of Parkinsonism.
Keywords/Search Tags:Imaging, Dopaminergic system, SPECT, Brain, Using, Parkinsonism, Degrading factors, 123I
Related items