Font Size: a A A

Thermal Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Water: Performance and Stability

Posted on:2014-09-05Degree:Ph.DType:Dissertation
University:The University of Wisconsin - MadisonCandidate:Lisowski, Darius DFull Text:PDF
GTID:1452390005485042Subject:Engineering
Abstract/Summary:
This experimental study investigated the thermal hydraulic behavior and boiling mechanisms present in a scaled reactor cavity cooling system (RCCS).;The experimental facility reflects a ¼ scale model of one conceptual design for decay heat removal in advanced GenIV nuclear reactors. Radiant heaters supply up to 25 kW/m2 onto a three parallel riser tube and cooling panel test section assembly, representative of a 5° sector model of the full scale concept. Derived similarity relations have preserved the thermal hydraulic flow patterns and integral system response, ensuring relevant data and similarity among scales. Attention will first be given to the characterization of design features, form and heat losses, nominal behavior, repeatability, and data uncertainty. Then, tests performed in single-phase have evaluated the steady-state behavior. Following, the transition to saturation and subsequent boiling allowed investigations onto four parametric effects at two-phase flow and will be the primary focus area of remaining analysis.;Baseline conditions at two-phase flow were defined by 15.19 kW of heated power and 80% coolant inventory, and resulted in semi-periodic system oscillations by the mechanism of hydrostatic head fluctuations. Void generation was the result of adiabatic expansion of the fluid due to a reduction in hydrostatic head pressure, a phenomena similar to flashing. At higher powers of 17.84 and 20.49 kW, this effect was augmented, creating large flow excursions that followed a smooth and sinusoidal shaped path. Stabilization can occur if the steam outflow condition incorporates a nominal restriction, as it will serve to buffer the short time scale excursions of the gas space pressure and dampen oscillations. The influences of an inlet restriction, imposed by an orifice plate, introduced subcooling boiling within the heated core and resulted in chaotic interactions among the parallel risers. The penultimate parametric examined effects of boil-off and inventory loss, where five different stages of natural circulation flow were identified: single-phase heating, transitional nucleate boiling, hydrostatic head fluctuations, stable two-phase flow, and geysering. Finally, the implementation of the model RCCS to a full scale plant was investigated by a multivariate test simulating an hypothetical accident scenario.
Keywords/Search Tags:Thermal hydraulic, System, Cooling, Experimental, Scale, Boiling
Related items