| From structural analysis stand of view, all elements of the structure are closely connected to form a space structure to sustain various loads from many directions. The element may be jointed with others out of its plane as a three-dimension bearing system. The high sluice pier in hydraulic project is not only subjected to self-weight load, but also longitudinal and crosswise water load.Tao Hua power plant of high sluice pier , The Guizhou Province Duyun city,is designed to reinforced concrete structure, its hight is 21.7 meters, the thickness is only 1.5 meters. This paper carries on the structure analysis to its high sluice pier. through the finite elemental method rationale with software ANSYS to its high sluice pier. The finite element analysis is applied to structure and can provide date and results for the design. Above this, the means can be reference to the analysis of the same type structural.This paper is consisted of several parts shown as following.1. After some simplifications of structure the paper, we created the three dimensional finite element model corresponded to the actual building .2. Through calculation and analysis of structural model under dead load and water load , the paper derived the non-seismic internal force and deforming of the structure.3. Through the analysis the internal force and deforming of the stuctural, the paper provide some value suggestion for the structural. |